|
Specim Spectral Imaging
vnir hyperspectral imaging system with a pgp spectrograph Vnir Hyperspectral Imaging System With A Pgp Spectrograph, supplied by Specim Spectral Imaging, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/hyperspectral+imaging+spectrograph/vnir+hyperspectral+imaging+system+with+a+pgp+spectrograph/pm40573518-39-14-17 Average 90 stars, based on 1 article reviews
vnir hyperspectral imaging system with a pgp spectrograph - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Specim Spectral Imaging
hyperspectral line camera specim imspector ® vnir v10-e spectrograph ![]() Hyperspectral Line Camera Specim Imspector ® Vnir V10 E Spectrograph, supplied by Specim Spectral Imaging, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/hyperspectral+imaging+spectrograph/hyperspectral+line+camera+specim+imspector+++vnir+v10+e+spectrograph/pmc11559659-305-8-14 Average 90 stars, based on 1 article reviews
hyperspectral line camera specim imspector ® vnir v10-e spectrograph - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Gilden Photonics
hyper-spectral camera pushbroom type ![]() Hyper Spectral Camera Pushbroom Type, supplied by Gilden Photonics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/hyperspectral+imaging+spectrograph/push+broom+hyperspectral+imager++spectrograph++hs+spectral+camera+model/pmc06034441-220-2-7 Average 90 stars, based on 1 article reviews
hyper-spectral camera pushbroom type - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Headwall Photonics
hyperspectral camera equipped with a 16-bit mercury cadmium telluride array detector and an imaging spectrograph hyperspec-swir ![]() Hyperspectral Camera Equipped With A 16 Bit Mercury Cadmium Telluride Array Detector And An Imaging Spectrograph Hyperspec Swir, supplied by Headwall Photonics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/hyperspectral+imaging+spectrograph/hyperspectral+camera+equipped+with+a+16+bit+mercury+cadmium+telluride+array+detector+and+an+imaging+spectrograph+hyperspec+swir/pm38005450-141-24-27 Average 90 stars, based on 1 article reviews
hyperspectral camera equipped with a 16-bit mercury cadmium telluride array detector and an imaging spectrograph hyperspec-swir - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Specim Spectral Imaging
hyperspectral camera with an imspector v10 spectrograph ![]() Hyperspectral Camera With An Imspector V10 Spectrograph, supplied by Specim Spectral Imaging, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/hyperspectral+imaging+spectrograph/hyperspectral+camera+with+an+imspector+v10+spectrograph/10__1007_slash_s12230___017___9595___z-84-5-12 Average 90 stars, based on 1 article reviews
hyperspectral camera with an imspector v10 spectrograph - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Specim Spectral Imaging
hyperspectral imaging system v10 spectrograph ![]() Hyperspectral Imaging System V10 Spectrograph, supplied by Specim Spectral Imaging, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/hyperspectral+imaging+spectrograph/hyperspectral+imaging+system+v10+spectrograph/10__1016_slash_j__postharvbio__2005__02__015-60-0-27 Average 90 stars, based on 1 article reviews
hyperspectral imaging system v10 spectrograph - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Princeton Instruments
hyperspectral imaging spectrograph ![]() Hyperspectral Imaging Spectrograph, supplied by Princeton Instruments, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/hyperspectral+imaging+spectrograph/hyperspectral+imaging+spectrograph/pm41702901-274-7-10 Average 86 stars, based on 1 article reviews
hyperspectral imaging spectrograph - by Bioz Stars,
2026-11
86/100 stars
|
Buy from Supplier |
Image Search Results
Journal: Journal of Biomedical Optics
Article Title: Hyperspectral imaging in neurosurgery: a review of systems, computational methods, and clinical applications
doi: 10.1117/1.JBO.30.2.023512
Figure Lengend Snippet: Hyperspectral imaging technologies used in neurosurgery. (a) Hyperspectral image cube is an array of size W × H × N , where W and H are the width and height, respectively, of images in the cube along the x and y spatial dimensions, and N is the number of wavelength channels along the λ dimension. Each W × H channel in the cube is equivalent to an image that would be captured by placing an appropriate bandpass spectral filter in front of the camera. (b) Point scanning methods acquire a complete spectrum at a single ( x , y ) pixel coordinate (i.e., “point”), scanning along the x and y spatial dimensions to reconstruct the full 3D hyperspectral cube. (c) Line scanning methods acquire 2D data of size W × N along one x spatial dimension, scanning along the y spatial dimension (i.e., “line”) to reconstruct the full 3D hyperspectral cube. (d) Spectral scanning methods acquire 2D data images of size W × H at one λ wavelength channel, scanning along the λ wavelength dimension (i.e., “spectral”) to reconstruct the full 3D hyperspectral cube. (e) Snapshot methods acquire the full 3D hyperspectral image cube of size W × H × N with each single acquisition (i.e., “snapshot”).
Article Snippet: Follow-up work in the HELICoiD project used other
Techniques: Imaging
Journal: Journal of Biomedical Optics
Article Title: Hyperspectral imaging in neurosurgery: a review of systems, computational methods, and clinical applications
doi: 10.1117/1.JBO.30.2.023512
Figure Lengend Snippet: HSI systems in neurosurgery. (a) HELICoiD system uses an exoscope with two line-scan hyperspectral cameras mounted in a confocal configuration. The HELICoiD system fits within a 60 × 60 × cm bounding and requires removing the surgical microscope for acquisition, thus interrupting the surgical workflow. (b) Small footprint handheld HSI snapshot system does not require removing the surgical microscope but does not provide the same field of view as seen from the surgeon’s oculars. (c) and (d) HSI systems [spectral scanning in panel (c) and snapscan in panel (d)] mounted on one of the side ports of the surgical microscope enable the acquisition of 3D hyperspectral image cubes co-registered with the surgeon’s field of view with a small physical footprint to seamlessly integrate into the already space-constrained neurosurgical operating room. (a) Adapted from Leon et al., under CC-BY 4.0. (b) Adapted from MacCormac et al., under CC-BY 4.0. (c) Reproduced from Valdés et al., under CC-NC-SA 3.0. (d) Adapted from Kifle et al., under CC-BY 4.0.
Article Snippet: Follow-up work in the HELICoiD project used other
Techniques: Microscopy
Journal: Journal of Biomedical Optics
Article Title: Hyperspectral imaging in neurosurgery: a review of systems, computational methods, and clinical applications
doi: 10.1117/1.JBO.30.2.023512
Figure Lengend Snippet: Technical specifications of current hyperspectral imaging systems in neurosurgery (as applied in individual work).
Article Snippet: Follow-up work in the HELICoiD project used other
Techniques: Imaging, Concentration Assay, Comparison, Functional Assay
Journal: Journal of Biomedical Optics
Article Title: Hyperspectral imaging in neurosurgery: a review of systems, computational methods, and clinical applications
doi: 10.1117/1.JBO.30.2.023512
Figure Lengend Snippet: Computational methods developed for hyperspectral imaging in neurosurgery.
Article Snippet: Follow-up work in the HELICoiD project used other
Techniques: Imaging, Biomarker Discovery, Histopathology, Ex Vivo, Selection, Transformation Assay, Concentration Assay, Fluorescence, Mutagenesis, Comparison, Single Photon Emission Computed Tomography, Functional Assay, Marker
Journal: Journal of Biomedical Optics
Article Title: Hyperspectral imaging in neurosurgery: a review of systems, computational methods, and clinical applications
doi: 10.1117/1.JBO.30.2.023512
Figure Lengend Snippet: Classifying brain tissue types based on reflectance spectra. Left to right: intraoperative hyperspectral reflectance imaging on four patients with glioma grades 2 and 4 using the HELICoiD system (patient 1 in row 1, patient 2 in rows 2 and 4, patient 3 in row 3, and patient 4 in row 5), white-light synthetic RGB image reconstructed from the hyperspectral cube with tumor regions marked in yellow and biopsy sites with black circles, ground truth–labeled pixels and pixel classifications using linear unmixing methods [extended blind end-member and abundance extraction (EBEAE)], , and a two-layer pixel-wise DNN. The four classes are NT, TT, BV, and BG. EBEAE yields around 60% overall accuracy, 30% tumor sensitivity, and 85% tumor specificity, whereas the DNN yields 85% overall accuracy, 65% tumor sensitivity, and 95% tumor specificity with fivefold cross-validation on mixed-patient pixel-wise data. GBM, glioblastoma; OD, oligodedrogioma; A, astrocytoma. Adapted from Leon et al., under CC-BY 4.0.
Article Snippet: Follow-up work in the HELICoiD project used other
Techniques: Imaging, Labeling, Extraction, Biomarker Discovery
Journal: Journal of Biomedical Optics
Article Title: Hyperspectral imaging in neurosurgery: a review of systems, computational methods, and clinical applications
doi: 10.1117/1.JBO.30.2.023512
Figure Lengend Snippet: Clinical validation of hyperspectral imaging systems for neurosurgical applications.
Article Snippet: Follow-up work in the HELICoiD project used other
Techniques: Biomarker Discovery, Imaging, Labeling, Ex Vivo, Selection, In Vitro, Microscopy, Fluorescence, Concentration Assay, Drug discovery, Mutagenesis, Functional Assay, In Vivo Imaging
Fig. 4(b) ] were captured during the resection of glioblastoma with images at the beginning (a)–(c), near end (e)–(g), and end of the surgery (i)–(k). The first three columns show (from left to right) RGB images reconstructed from the hyperspectral cube (white light), co-registered fluorescence images using the conventional fluorescence surgical microscope (conventional fluorescence), and PpIX concentration maps estimated from hyperspectral cubes (hyperspectral quantitative fluorescence). (d) In vivo fluorescence spectra acquired from three locations and marked by different colored crosses (+) in panel (a) with a high-intensity PpIX spectrum, and peak in red (+) matches the visible pink fluorescence in the center of tumor (b); an intermediate intensity PpIX spectrum and peak in blue (+) with no visible pink fluorescence is close to tumor in panel (b); and no PpIX spectrum and peak in green (+) matching no visible pink fluorescence far from tumor in panel (b). (h) In vivo fluorescence spectra acquired from one location and marked by a blue colored cross (+) in panel (e) show an intermediate intensity PpIX spectrum and peak in blue (+), no visible pink fluorescence in panel (f), high estimated PpIX concentrations in panel (g), and are validated with pathology as tumor-infiltrated tissue in panel (l). In panels (d) and (h), the y -axis shows the intensity of fluorescence emission in arbitrary units, and the x -axis shows the wavelength λ in nanometers. vFI, visible fluorescence with the conventional microscope; qFI, quantitative fluorescence imaging estimates of PpIX. Reproduced from Valdés et al., under CC-NC-SA 3.0. " width="100%" height="100%">
Journal: Journal of Biomedical Optics
Article Title: Hyperspectral imaging in neurosurgery: a review of systems, computational methods, and clinical applications
doi: 10.1117/1.JBO.30.2.023512
Figure Lengend Snippet: In vivo hyperspectral fluorescence imaging of PpIX in a glioblastoma patient. Intraoperative images using a spectral scanning system [
Article Snippet: Follow-up work in the HELICoiD project used other
Techniques: In Vivo, Fluorescence, Imaging, Microscopy, Concentration Assay
Journal: Journal of Biomedical Optics
Article Title: Hyperspectral imaging in neurosurgery: a review of systems, computational methods, and clinical applications
doi: 10.1117/1.JBO.30.2.023512
Figure Lengend Snippet: Comparison of HSI to point spectroscopy. Point spectroscopy provides gold standard spectrally resolved measurements and PpIX concentration estimates that can be used to validate the estimates from hyperspectral processing. HSI extends the applicability of fluorescence guidance to WHO grade III anaplastic oligoastrocytomas (AOA) (a)–(e) and meningiomas (MEN) (f)–(j), where the PpIX concentration is significantly less than the limit for visual fluorescence. (k) Fluorescence spectra fit and estimated PpIX concentrations from HSI (top) and point spectroscopy measurements (bottom). MR texture map = matching MRI 2D image; Zeiss—white = white-light image from a conventional Zeiss microscope; Zeiss—blue = fluorescence image from a conventional Zeiss microscope; integrated fluorescence = map of fluorescence calculated from the area under the fluorescence spectrum from 620 to 650 nm; quantitative PpIX = map of PpIX concentration estimates. Reproduced from Bravo et al., under CC-BY 4.0.
Article Snippet: Follow-up work in the HELICoiD project used other
Techniques: Comparison, Spectroscopy, Concentration Assay, Fluorescence, Microscopy